Protection Relays for Power Transmission and Distribution
What the Network Demands
A transmission or distribution substation fails in one of four places: a fault on the line, a fault inside the transformer or busbar, a failure of the interrupting device to clear it, or a loss of the auxiliary supply that is supposed to detect it. Protection has to clear the fault in the first zone without tripping healthy feeders, and it has to do so with the station unattended and the SCADA link carrying the evidence afterwards.
That means distance or differential line protection with teleprotection, transformer differential with inrush restraint and unrestrained high-set, busbar differential, breaker failure, and a fault recorder that captures the sequence so the event can be reconstructed weeks later.
Devices We Supply for Substations
- ASL-441H line protection relay – overcurrent, earth fault and auto-reclose for distribution feeders
- Line distance protection relay (ANSI 21) – distance zones with power swing blocking for subtransmission
- ASL-441XLH line differential relay (87L) – current differential over fibre for cable and short overhead lines
- AST-441H 87T relay – two-winding transformer protection
- Three-winding transformer differential protection – for three-winding transformers and autotransformers
- 87B busbar differential protection panel – high-impedance or low-impedance busbar scheme
- DTU-380H distributed DTU (IEC 61850) – feeder automation terminal for remote-controlled ring main units
- ATN-800H arc flash protection relay – optical arc detection with fast trip for switchgear
- DFR/FDR-16B digital fault recorder – disturbance recording for post-event analysis
- ASM81H communication management unit / RTU – gateway to the control centre
Typical Functions on the Single-Line
Overcurrent and earth fault (50/51, 50N/51N), directional overcurrent (67), distance (21), line differential (87L), transformer differential (87T), restricted earth fault (87N), busbar differential (87B), breaker failure (50BF), under and over voltage (27/59), frequency (81U/81O), and auto-reclose (79). Feeder automation uses fault passage indication plus remote control so that a fault is isolated and healthy sections restored without a crew driving the line.
Documents for the Design Office
Protection settings cannot be written without the CT ratios, the fault level and the coordination study. Send those three to our engineering team with the single-line diagram and we will return the device list with the setting ranges that cover your fault level.
Common Specifications
| Ambient operating range | -25 to +55 °C |
| Rated frequency | 50 / 60 Hz |
| Routine testing | IEC 60255 routine tests on every unit before shipment |
| Communication | IEC 61850, Modbus RTU / TCP where specified on the datasheet |
| Mounting | Panel, rack or switchgear cubicle, per product |
| Certification | CE; quality system certified to ISO 9001:2015 |
Ordering and Documentation
Minimum order quantity is 1 unit. Standard lead time is 7 to 15 working days, with EXW, FOB, CIF or DDU terms as agreed on the quotation. Every order ships with the datasheet, manual, connection diagram and factory routine test report matched to the exact model and firmware version. See Technical Downloads for the document set and Quality and Certifications for the CE certificate, ISO 9001:2015 certificate and type test reports.
OEM and ODM supply is available: branding, labelling, document sets and enclosure details are agreed in writing before production. All equipment carries a 12-month warranty against manufacturing defects.
Send the single-line diagram, CT/VT ratios and the protection functions you need to our engineering team and we will return the matching configuration, documents and quotation.