Case

Case Study: Mudra Building Materials Self-Use Power Generation Project, Nigeria
Self-use power generation project case study from Nigeria: Mudra Building Materials runs a 3000 kW captive generator set on a generator protection cabinet and a separate synchronizing panel, with 87G differential, 64R rotor earth fault and ANSI 25 synchronism check.…

Supply Case of Low-Voltage PV Reverse Power Protection Equipment in Sri Lanka | Solution for Self-Consumption PV Projects
Low-voltage PV reverse power protection is the ANSI 32 scheme that stops a self-consumption photovoltaic plant from exporting surplus power into the public grid, and this page documents the 400 V supply case delivered to a renewable energy EPC contractor…

Rotor Earth Fault Protection Supply Case: What Pacific Engineering Shipped
A rotor earth fault protection supply case is a complete replacement supply for ANSI function 64R rotor earth fault protection on a synchronous generator. This one went to a Pakistani industrial client as a SEG Woodward XR-1 equivalent. At a…

Renovation Scheme for Generator and Transformer Protection Cabinets, Yongshan No.5 Hydropower Station, Vietnam
Generator and transformer protection cabinet renovation at Yongshan No.5 Hydropower Station in Vietnam replaced a pair of integrated devices with separate ones for each function. The station runs a single 14 MW generator at 11 kV, stepped up to 115…

Case Study: Complete Protection and Control Panel Supply for a 110kV Substation in Uzbekistan
Protection and control panel supply for a 110kV substation in Uzbekistan covered five panel types: AC/DC distribution, energy metering, central alarm and annunciation, main transformer protection and transmission line protection. We re-engineered the customer’s own drawings around our relays, built the…

Hydropower Plant Upgrade Solution 2026 for Vietnam
Hydropower plant upgrade solutions replace the protection, excitation, synchronising and control layers of a station that is already generating, without rebuilding the dam, the powerhouse or the waterway. The civil works stay. The relay panel, the excitation cubicle and the…

Application of Relay Protection and Automation in 3 MW Rooftop Photovoltaic Solar Power Systems
Relay protection for PV power systems watches four current paths: the inverter AC terminal, the collector line, the step-up transformer or bus, and the point where the plant meets the utility grid. ANSI functions 51/51N, 27/59 and 81 cover those paths,…