-
Leon Zhang Sales Manager
-
Email: sale@relayprotect.com
-
Phone/WhatsApp: +86 13655813266
Protection Relays for International Projects
Autony supplies ANSI-numbered protection relays and protection panels to utilities, EPC contractors and panel builders in 43 countries. The range covers line, transformer, generator, busbar and motor differential protection (87L, 87T, 87G, 87B, 87M), directional and non-directional overcurrent (67, 67N, 50/51), rotor earth fault (64R), reverse power (32) and voltage/frequency protection (27/59, 81). The plant has been ISO 9001:2015 certified since 2002 (certificate 41925Q10467-06R0S), and more than 200,000 relay sets are in service worldwide.
What a buyer outside the US usually needs
Most tender documents written outside the United States still name protection functions in ANSI device numbers, even when the utility’s own drawings use IEC symbols. That is the language our catalogue is built in: you specify 87T for a transformer, 87B for a busbar, 67N for a directional earth fault, and the relay you receive is documented the same way.
Three things decide whether a relay order actually works on site, and all three are settled before the purchase order:
- What the scheme protects — the voltage level, the number of windings or feeders, and whether the differential needs CT ratio and vector-group compensation inside the relay.
- How it trips — trip logic, trip circuit supervision, and whether the output has to drive a lockout relay in a control panel.
- How it talks — IEC 61850, Modbus RTU/TCP or hard-wired contacts, and which of those the SCADA integrator actually expects.
The range, by protection function
| Function | ANSI | Typical application | Page |
|---|---|---|---|
| Line current differential | 87L | Transmission and sub-transmission lines with a communications channel | 87L overview |
| Transformer differential | 87T | Two- and three-winding power transformers | 87T relay |
| Busbar differential | 87B | Single- and double-busbar substations | Differential protection |
| Generator differential | 87G | Generator stator protection | 87G relay |
| Motor differential | 87M | Large MV motors | 87M relay |
| Directional overcurrent | 67 / 67N | Parallel feeders, ring networks, directional earth fault | 67 / 67N |
| Rotor earth fault | 64R | Generator rotor insulation monitoring | 64R relay |
| Reverse power | 32 | Generator motoring protection, tie-line reverse flow | ANSI 32 relay |
Documentation and export paperwork
Every project has a different customs and utility requirement. Tell us up front which documents your side needs — routine test report, certificate of origin, packing list, wiring diagram or a certificate copy for the tender file — and we will confirm what can be issued with the order before you commit. Nothing is promised after the goods have shipped.
Who answers your messages
Enquiries go to a sales engineer, not a ticket queue: WhatsApp +86 136 5581 3266. That number reaches our sales manager Leon Zhang, who has spent 15 years selling protection relays to overseas utilities and panel builders. If a specification is ambiguous, the fastest path is a photo of the single-line diagram and the CT ratio — most scheme questions are answered from those two.
What to send with an enquiry
- Single-line diagram, or the protection function list (ANSI numbers are enough).
- System voltage and rated current, plus CT ratios if they are already fixed.
- Auxiliary supply available in the panel.
- Communication protocol required by the SCADA integrator, if any.
- Panel format — relay only, or a complete protection and control panel.
- Destination country, and the documentation your customs broker asks for.
Send those six items on WhatsApp or through the quotation form, and you get a specification-matched reply instead of a catalogue PDF.
Questions buyers ask before the first order
Can you supply relays documented in ANSI device numbers?
Yes — the catalogue is organised by ANSI number, and relay manuals and test reports use the same numbering, so a utility reviewer can check the function against the tender document directly.
Do you supply complete protection panels, not only relays?
Yes. Protection and control panels are one of the seven product categories, which matters when the scope includes CT/VT marshalling, trip circuits and panel wiring rather than a loose relay.
How is a multi-winding transformer scheme handled?
The 87T relay performs CT ratio and vector-group compensation internally, so a three-winding transformer can be protected without external interposing transformers. The three-winding 87T page lists the supported configurations.
What about certification for a tender file?
The plant is ISO 9001:2015 certified (certificate 41925Q10467-06R0S) and a certificate copy can be included. If your tender names another standard, send the clause and we will tell you what applies — we do not claim compliance with a standard we have not been certified against.
Which markets do you already ship to?
43 countries, with the largest share of enquiries coming from South Asia, the Middle East, Southeast Asia, Australia and Africa. References can be discussed per market on request.
If your tender file needs the paperwork, the quality certifications page lists the ISO certificates, the standards we helped to write and the test reports, and the project track record shows the countries and voltage levels already delivered.
Next step: send the single-line diagram or the ANSI function list on WhatsApp +86 136 5581 3266, or read the ordering guide.
Buying for a project inside the United States? The US utilities and OEM page covers the same range with the specification language American reviewers expect.
