We sell direct from the factory rather than through a marketplace, so buying is a short conversation with an engineer instead of a checkout page. This page explains what happens after you send an enquiry – what we need from you, what you get back, and the commercial terms that apply.

At a glance: minimum order 1 unit. Standard models ship in 7-15 working days. Every enquiry is answered within 12 hours, 09:00-17:00 (UTC+8), Monday to Sunday. Trade terms EXW, FOB, CIF or DDU. Payment by T/T, L/C, Western Union or PayPal. Every product carries a 12-month warranty.

Two situations cover most first enquiries: a single relay for a retrofit, and a project list that has to be quoted line by line. Both are handled the same way – send the application, get a model match and a quotation with the trade terms already stated.

1. Send your requirements

Tell us the application: rated voltage, CT/VT ratios if you have them, the protection functions you need (for example ANSI 87T, 87G, 87L, 51N, 21 or 32), the panel or switchgear it goes into, and any communication requirement (IEC 61850, Modbus or RS-485). If you only have a single-line diagram or a photo of the existing relay, that is enough to start.

2. Get a model match and a quotation

We reply with the model that fits the application, the datasheet and wiring drawing, and a quotation. If a smaller unit covers your scheme we will say so – the aim is a relay that is correct for the protection scheme, not the largest one in the range.

3. Sample or bulk order

MOQ starts at 1 unit for samples. Bulk orders typically ship in 7-15 working days depending on quantity and customization. Shipping terms: EXW, FOB, CIF or DDU. Payment by T/T, L/C, Western Union or PayPal.

4. Setting, testing and commissioning support

We provide free technical guidance, parameter setting and commissioning support, so the relay goes into service with the settings your scheme needs. All products carry a 12-month warranty against manufacturing defects.

Send a BOM or a multi-item project list

Project lists are quoted line by line. Send the BOM, the equipment schedule or the drawing package in any format: Excel, PDF or a photo of a printed list. Each line is matched to a model and the quotation carries your line number next to the matched model, so the panel builder or the EPC contractor can check it without cross-referencing part numbers. If two lines can be served by the same model, the quotation says so.

Mixed lists are normal. Relays, protection and control panels, communication units and auxiliary equipment can be quoted on one document under one set of trade terms. Give the required on-site date and it is checked against the production schedule before the quotation is issued.

What drives the price

Protection equipment is configured to the scheme, so the price follows the configuration rather than a fixed list price. The factors that move it most:

  • Protection functions required. A feeder relay with overcurrent and earth fault costs less than a multi-function unit carrying distance, differential and breaker failure functions.
  • Communication. IEC 61850, Modbus RTU or a protocol gateway changes the board set and therefore the configuration.
  • Form of supply. A relay alone, a relay mounted in a panel, or a complete protection and control panel with wiring and factory acceptance testing.
  • Voltage class, CT and VT ratios, and the number of bays or feeders on one scheme.
  • Quantity and delivery date. Standard production against an expedited slot.
  • Documentation and testing scope. Routine factory test report, or witnessed factory acceptance testing with client attendance.

If you are working to a budget, state the budget and the function set can be adjusted to fit, instead of quoting a scheme that cannot be approved.

What ships with an order

A relay is delivered with the operation manual, the wiring schematic, the parameter setting guide and the factory inspection report – the four documents a commissioning engineer needs on site.

A protection and control panel is delivered with the general arrangement drawing, the schematic and terminal connection diagrams, the bill of materials, the relay setting schedule, the factory acceptance test report, the operation and maintenance manual, the communication protocol mapping and the certificate of conformance. As-built drawings are added where the project specification requires them.

Questions buyers ask before ordering

Do you supply direct, or do I have to go through a distributor?

Direct. The equipment is manufactured in our own plant and ships from it, so there is no distributor margin and no marketplace intermediary between the enquiry and the quotation. On projects specified by EPC contractors, panel builders or system integrators, we quote to the contractor and support the specification through to commissioning.

Can you quote from a BOM or a multi-item list?

Yes. Send the list in any format and each line is matched to a model. The quotation returns your line numbers with the matched model, the unit price and the trade term. Enquiries are answered within 12 hours, 09:00-17:00 (UTC+8), Monday to Sunday.

What is the minimum order quantity?

One unit. A single set can be ordered for evaluation, for a pilot installation or to replace one failed relay, and project quantities are quoted separately.

What is the lead time?

Standard models ship in 7-15 working days after the order is confirmed. Custom ratings, protocols or mounting arrangements are confirmed in writing before the order is placed, so the delivery date is known in advance.

Which payment methods and trade terms do you accept?

Payment by T/T, L/C, Western Union or PayPal. Trade terms are EXW, FOB, CIF or DDU, chosen to match how the consignment is collected.

What documents are supplied with a relay or a panel?

A relay ships with the operation manual, the wiring schematic, the parameter setting guide and the factory inspection report. A panel adds the general arrangement drawing, terminal connection diagrams, the bill of materials, the relay setting schedule, the factory acceptance test report, the protocol mapping and the certificate of conformance.

Is commissioning support included, and who does the setting?

Technical guidance, parameter setting and commissioning support are provided, so the relay goes into service with the settings the scheme needs. The relay setting schedule supplied with a panel lists the settings, and the support continues through the service life of the equipment.

What if I only have a single-line diagram or a photo of the existing relay?

That is enough to start. A single-line diagram, a photo of the nameplate and the ratings are sufficient to identify the model and the protection functions that have to be replaced or extended. Full specifications are not needed for the first reply.

Start a quote request

Use the form on our contact page or email us directly – include the model or the application and we will come back with a quotation. Browsing first? The main groups are substation protection relays, generator protection, motor protection, renewable energy protection, distribution automation, auxiliary equipment and protection and control panels.

Buying from outside the United States?

Orders shipped outside the US usually need a different document set and a faster channel than email. The international project page lists the six items that make a specification-matched quotation possible, and the WhatsApp number that reaches a sales engineer directly.

High Quality

Stable performance, reliable design, ensuring safe operation for power system protection and grid stability.

Fast Delivery

Timely delivery to support your urgent orders and project schedules efficiently and professionally at any time.

Best Warranty

Professional Warranty: Reliable after-sales support for stable relay protection and long-term customer satisfaction.