Leon Zhang Sales Manager
-
Email: sale@relayprotect.com
-
Phone/WhatsApp: +86 13655813266
Protection Relays for US Utilities and OEMs
Autony builds ANSI-numbered protection relays and protection panels for US utilities, EPC contractors and OEM panel shops. The range covers transformer, busbar, generator, line and motor differential protection (87T, 87B, 87G, 87L, 87M), directional overcurrent (67/67N), rotor earth fault (64R), reverse power (32) and voltage/frequency protection (27/59, 81). The plant is ISO 9001:2015 certified (certificate 41925Q10467-06R0S) and has been in operation since 2002, with more than 200,000 relay sets in service.
Why a US project starts with the device number
American relay settings and coordination studies are written in ANSI device numbers, and the same numbers appear on the panel drawing, the test report and the relay front plate. Everything we publish is organised that way, so a protection engineer can check the function against the coordination study without translating nomenclature first.
Functions most often specified for US projects
- 87T — two- and three-winding transformer differential with internal CT ratio and vector-group compensation.
- 87B — busbar differential for single- and double-busbar arrangements.
- 67 / 67N — directional phase and earth overcurrent for parallel transformers and ring buses.
- 64R — generator rotor earth fault, alarm on the first fault and trip on the second.
- 32 — reverse power for generator motoring protection and tie-line reverse flow.
- 50/51 — instantaneous and time-overcurrent backup, coordinated from the study curves.
Working with a US buyer
Three practical points come up on almost every US enquiry:
- Standards language. If the specification cites a standard, send the clause. We will say which requirement our documentation answers and which it does not — we do not claim certification we do not hold.
- Documentation set. Routine test reports, wiring diagrams and certificate copies can be prepared per order; tell us what the utility reviewer needs before the purchase order, not after.
- Time zone. Enquiries reach a sales engineer directly on WhatsApp +86 136 5581 3266, and replies are usually same-day within the working window.
Specify in one message
Send the single-line diagram (or the ANSI function list), the system voltage and CT ratios, the auxiliary supply available in the panel, and the protocol your SCADA integrator expects. That is enough for a specification-matched reply. The ordering guide lists the full input set, and the substation protection relay range shows what ships as a standard product.
Questions from US buyers
Do you supply 60 Hz applications?
Frequency is a setting, not a separate model: the rating you need is confirmed against the order specification before the relay is configured. State 60 Hz on the enquiry and it is checked at quotation.
Can a relay be supplied for a retrofit into an existing panel?
Yes, and the retrofit case is the one where the panel drawing matters most — terminal arrangement, trip circuit voltage and the existing CT ratios all have to line up. Send a photo of the existing relay nameplate and the panel wiring.
Are complete protection panels available?
Yes. Protection and control panels are a separate product category, covering CT/VT marshalling, trip circuits and panel wiring when the scope is wider than a loose relay.
Who do I talk to?
Leon Zhang, Sales Manager, 15 years selling protection relays — reachable on WhatsApp +86 136 5581 3266 or through the quotation form.
Shipping outside the United States? The international projects page covers export documentation, tender paperwork and direct WhatsApp contact.