Protection Relays for Water Conservancy and Hydropower
Small Hydro Has the Full Generator Problem
A 3 MW hydro unit has every protection problem a 300 MW unit has, in one cubicle. Stator winding faults need differential protection. The rotor circuit needs earth fault detection, and on a static excitation system that requires voltage injection because the field circuit is not earthed through a slip ring any more. Loss of excitation, reverse power when the guide vanes close, over and under frequency when the unit is islanded, and out-of-step conditions all have to be covered before the generator is connected to the grid.
A pumping station has a different set of problems: several large synchronous or induction motors that must start in sequence without collapsing the supply, and a control system that has to run the pumps unattended.
Devices We Supply for Hydro and Pumping Stations
- AGP-441H generator differential protection relay (87G) – stator winding differential
- 64R rotor earth fault protection relay – field circuit earth fault
- Rotor earth fault protection by voltage injection – for static excitation systems
- 87G / 50 / 51 generator protective relay – combined differential and backup overcurrent
- Generator backup protection relay – impedance backup, loss of excitation, reverse power
- ANSI 32 reverse power protection relay – motoring protection for the unit
- Generator synchronization panel (ANSI 25/25A/27/59/81) – automatic synchronising and check synchronising
- ATN-400 excitation panel – excitation control cabinet for synchronous generators
- ASF-441H anti-islanding protection device – disconnects the unit when the grid is lost
- PLC control panel for hydropower and pumping stations – pump sequencing and unit automation
- 400 V low voltage hydroelectric generator protection relay – small units
Anti-Islanding Is a Grid Requirement
When the utility feeder opens, an embedded generator that keeps energising the island endangers the line crew and prevents the automatic reclosing of the feeder. The anti-islanding function must detect the loss of mains and disconnect within the time the network operator specifies. The ASF-441H and ASF-442H provide that function together with the voltage and frequency limits the operator requires.
Pumping Stations Live or Die on Starting Sequence
Three 400 kW pumps starting simultaneously will trip the transformer; started in sequence against the correct valve position, they will not. The PLC control panel handles the sequence, the interlocks and the level control, and it integrates with the motor protection relays so that a fault on one pump does not stop the station.
Send the Unit Data
Send the generator rating, excitation type (static or brushless), earthing arrangement, the network operator’s anti-islanding requirement and the pump list to our engineering team. We will return the protection scheme, the setting guidance and the quotation.
Common Specifications
| Ambient operating range | -25 to +55 °C |
| Rated frequency | 50 / 60 Hz |
| Routine testing | IEC 60255 routine tests on every unit before shipment |
| Communication | IEC 61850, Modbus RTU / TCP where specified on the datasheet |
| Mounting | Panel, rack or switchgear cubicle, per product |
| Certification | CE; quality system certified to ISO 9001:2015 |
Ordering and Documentation
Minimum order quantity is 1 unit. Standard lead time is 7 to 15 working days, with EXW, FOB, CIF or DDU terms as agreed on the quotation. Every order ships with the datasheet, manual, connection diagram and factory routine test report matched to the exact model and firmware version. See Technical Downloads for the document set and Quality and Certifications for the CE certificate, ISO 9001:2015 certificate and type test reports.
OEM and ODM supply is available: branding, labelling, document sets and enclosure details are agreed in writing before production. All equipment carries a 12-month warranty against manufacturing defects.
Send the single-line diagram, CT/VT ratios and the protection functions you need to our engineering team and we will return the matching configuration, documents and quotation.