Leon Zhang sales consultant
-
Email: zxl635973785@gmail.com
-
Phone/WhatsApp: +86 13655813266
Blog
Transformer Differential Protection Testing: Methods, Procedures

Transformer differential protection testing confirms two things: the 87T relay trips for internal faults, and it stays stable through inrush and through-faults. Factory defaults prove neither. Commissioning before energization, and re-testing at every maintenance interval, is what closes the gap. Written by…
Differential Protection Setting Calculation: Pickup, Slope and Stability Formulas

Differential protection setting calculation fixes four numbers for one protection zone: the differential pickup, the bias slope, the harmonic restraint ratio and the trip time. The same four numbers govern a transformer (87T), a generator (87G), a motor (87M), a busbar…
RMU Protection Relay for Medium-Voltage Ring Main Units

RMU protection relay choice is bounded by four things: the ANSI functions the ring needs (50/51 overcurrent, 50N/51N earth fault, 67N directional earth fault), the CT already fitted in the cubicle, the auxiliary supply, and the protocol your SCADA master…
Locked Rotor Protection Relay: ANSI 48/51LR Setting and Application

A locked rotor protection relay is the device that trips a motor when a start never completes. ANSI 48 watches the start as a sequence. ANSI 51LR adds a locked rotor overcurrent stage on top of that, and the ANSI…
Motor Protection Faults, Protection Schemes and ANSI Functions

Overview This paper mainly illustrates motor fault categories, protection schemes as well as relay setting calculation for motor protection, assisting overseas electrical engineers in mastering motor protection devices and their practical application specifications. 10kV high-voltage motors act as critical power…
Motor Protection Relay Manufacturer for Industrial and Power Applications

Motor protection relays for low-voltage and medium-voltage circuits are bought from somebody. Most project teams start that search on this page. A motor protection relay manufacturer has to answer four questions before a quotation is worth comparing: what the factory…
Transformer Differential Protection Working Principle: How 87T Protection Works

Transformer differential protection working principle is built on one check: compare the currents at the transformer boundaries. An ANSI 87T relay compares the currents entering and leaving the transformer after accounting for transformer ratio, phase displacement and current transformer characteristics. Written by…