Protection Relays for Building Materials and Cement Plants
Continuous Process, Intermittent Loads
Cement, glass and ceramics run continuously: a kiln that stops cools unevenly and the refractory lining is damaged, and a raw mill that trips on a fault takes the whole line with it. Yet the individual loads are violent – crushers and mills start against a full charge, fans and ID fans draw high current for long acceleration times, and the plant distribution is spread over hundreds of metres of cable, which makes earth fault detection harder than it looks.
So the electrical design is about two questions: does the motor protection survive a heavy start without tripping on a legitimate overload, and does the plant keep running when the incoming supply dips?
Devices We Supply for Cement and Building Materials Plants
- ASD-441H motor protection relay – mills, crushers, fans, conveyors; thermal replica overload with start supervision
- 87M motor differential protection – large mill and fan motors
- 83B automatic bus transfer switch – transfer to the standby incomer during a supply dip
- ASZ-526H low voltage ATS controller – generator and standby supply changeover
- ATN-800H arc flash protection relay – MCC and transformer rooms
- APQ-9100H power quality monitor – sags, harmonics and unbalance on the plant busbar
- AST-441H 87T relay – main and distribution transformers
- ASNM-611H digital multifunction power meter – energy and demand per department
Start Supervision Is What Makes It Work
A mill motor with a 30-second acceleration time at 3 times full load current will trip a standard inverse-time curve that was set for a pump. The relay must supervise the start: allow the locked-rotor current for the permitted time, alarm if the start is longer than the process allows, and block a restart until the thermal capacity has recovered. The ASD-441H provides that start supervision in addition to the standard overload and earth fault functions.
Voltage Dips Are the Real Outage Cause
Most cement plant stoppages are not equipment failures – they are voltage dips from the utility that trip contactors and drives. The APQ-9100H quantifies how deep and how often the dips are, which is the evidence needed to justify a ride-through setting or a fast bus transfer instead of an argument with the supplier.
Send the Motor and Drive List
Send the motor list with rated kW, starting method, acceleration time and duty cycle to our engineering team. We will return the relay model per motor and the start supervision settings.
Common Specifications
| Ambient operating range | -25 to +55 °C |
| Rated frequency | 50 / 60 Hz |
| Routine testing | IEC 60255 routine tests on every unit before shipment |
| Communication | IEC 61850, Modbus RTU / TCP where specified on the datasheet |
| Mounting | Panel, rack or switchgear cubicle, per product |
| Certification | CE; quality system certified to ISO 9001:2015 |
Ordering and Documentation
Minimum order quantity is 1 unit. Standard lead time is 7 to 15 working days, with EXW, FOB, CIF or DDU terms as agreed on the quotation. Every order ships with the datasheet, manual, connection diagram and factory routine test report matched to the exact model and firmware version. See Technical Downloads for the document set and Quality and Certifications for the CE certificate, ISO 9001:2015 certificate and type test reports.
OEM and ODM supply is available: branding, labelling, document sets and enclosure details are agreed in writing before production. All equipment carries a 12-month warranty against manufacturing defects.
Send the single-line diagram, CT/VT ratios and the protection functions you need to our engineering team and we will return the matching configuration, documents and quotation.