Industries Served
Protection Relays for Six Heavy Industries
Autony supplies protection relays, protection and control panels and substation automation equipment to power utilities and to the industrial plants that run their own generation and distribution: petrochemical, coal mining, metallurgy, building materials and water conservancy. The electrical problem differs in each of them; the device families and the engineering approach do not.
On all six, the same three things decide whether a fault becomes an outage: correct protection functions selected for the earthing system, a setting range that covers the actual load profile, and documentation that matches the firmware in the cubicle. Each industry page below sets out the functions we normally recommend, the devices we supply for them, and the failure modes that the protection has to cover.
Select Your Industry
- Power transmission and distribution – substation automation, line, transformer and busbar protection, feeder automation
- Petrochemical and chemical plants – motor protection, arc flash protection, load shedding, power quality
- Coal mining – unearthed and compensated network earth fault detection, feeder protection, motor protection
- Metallurgy and steel – resonance elimination, heavy motor protection, bus transfer, power quality
- Building materials and cement – bus transfer, mill and fan motor protection, arc flash protection
- Water conservancy and hydropower – generator protection, excitation, PLC control, anti-islanding
Why Plants Ask Us for the Whole Panel
Buying relays, wiring them into a cubicle and making the scheme work are three different jobs. We do all three: the same engineering team that designs the protection device also assembles the panel, writes the settings file and issues the drawing set, so the function you specified on the single-line diagram is the function that arrives in the switchgear room.
More than 200,000 protection devices are in service in substations and industrial plants, and our engineers have taken part in drafting national and industry standards for protection and automation equipment, including GB/T 35791-2017, GB/T 37763-2019 and NB/T 42166-2018.
Not Sure Which Functions You Need?
Send the single-line diagram, the CT and VT ratios, the earthing arrangement (solidly earthed, resistance earthed, isolated or compensated) and the load profile to our engineering team. We will return the recommended device list, the setting guidance and a quotation, normally within one working day.
Common Specifications
| Ambient operating range | -25 to +55 °C |
| Rated frequency | 50 / 60 Hz |
| Routine testing | IEC 60255 routine tests on every unit before shipment |
| Communication | IEC 61850, Modbus RTU / TCP where specified on the datasheet |
| Mounting | Panel, rack or switchgear cubicle, per product |
| Certification | CE; quality system certified to ISO 9001:2015 |
Ordering and Documentation
Minimum order quantity is 1 unit. Standard lead time is 7 to 15 working days, with EXW, FOB, CIF or DDU terms as agreed on the quotation. Every order ships with the datasheet, manual, connection diagram and factory routine test report matched to the exact model and firmware version. See Technical Downloads for the document set and Quality and Certifications for the CE certificate, ISO 9001:2015 certificate and type test reports.
OEM and ODM supply is available: branding, labelling, document sets and enclosure details are agreed in writing before production. All equipment carries a 12-month warranty against manufacturing defects.
Send the single-line diagram, CT/VT ratios and the protection functions you need to our engineering team and we will return the matching configuration, documents and quotation.